R27 Series

R27 Series

R27 Series

G1/4

Technical Data

Medium:
Dry, oil free air filtered to 25 microns
Operation:
Two stage servo mechanised regulator with integral precision
measuring capsule
Mounting:
Any position. Panel mounting or through mounting holes on
the unit (lever, plunger and pilot versions)
Port Sizes:
G1⁄4
Output Pressure ranges:
See individual details overleaf
Supply Pressure:
Minimum at least 0.2 bar above output pressure. Maximum
10 bar
Flow Capacity:
Up to 300 l/m.
Hysteresis and repeatability:
Less than 0.005% setting at midrange
Sensitivity:
Better than 0.3 mbar
Air Consumption:
See individual details overleaf